Neutron streaming through straight and single bend slots
Technical Report
·
OSTI ID:5889820
Calculations have been performed using the Monte Carlo code MCNP to determine the neutron streaming through various straight and single-bend slots in a one-meter-thick shield. A uniform plane source emitting 14-MeV neutrons with a cosine angular distribution was used in the analyses. The results obtained have direct implications regarding neutron-streaming problems that will be encountered in the shielding analyses of tokamak fusion reactors which are constructed from pie-shaped shield/vacuum chamber segments.
- Research Organization:
- Los Alamos National Lab., NM (USA)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 5889820
- Report Number(s):
- LA-9761-MS; ON: DE83015178
- Country of Publication:
- United States
- Language:
- English
Similar Records
Neutron streaming Monte Carlo radiation transport code MORSE-CG
Neutron streaming through shield ducts using a discrete ordinates/Monte Carlo method
Neutron streaming through diagnostic penetrations in a fusion reactor shield
Journal Article
·
Fri Oct 31 23:00:00 EST 1986
· Fusion Technol.; (United States)
·
OSTI ID:7182338
Neutron streaming through shield ducts using a discrete ordinates/Monte Carlo method
Conference
·
Wed Aug 18 00:00:00 EDT 1993
·
OSTI ID:10122551
Neutron streaming through diagnostic penetrations in a fusion reactor shield
Technical Report
·
Sun May 01 00:00:00 EDT 1983
·
OSTI ID:5435346