Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Prevention reference manual: chemical specific. Volume 1. Control of accidental releases of hydrogen fluoride (SCAQMD) (South Coast Air Quality Management District). Final report, May 1986-March 1987

Technical Report ·
OSTI ID:5885151
This manual summarizes technical information that will assist in identifying and controlling hydrogen fluoride release hazards specific to the South Coast Air Quality Management District (SCAQMD) of southern California. The SCAQMD has considered a strategy for reducing the risk of a major accidental air release of toxic chemicals. The strategy includes monitoring the storage, handling, and use of certain chemicals and provides guidance to industry and communities. Anhydrous hydrogen fluoride, a corrosive liquid that boils at room temperature, rapidly absorbs moisture to form highly corrosive hydrofluoric acid. Hydrogen fluoride gas has an IDLH (immediately dangerous to life and health) concentration of 20 ppm, which makes it a substantial acute toxic hazard. Reducing the risk associated with an accidental release of hydrogen fluoride involves identifying some of the potential causes of accidental releases that apply to the processes that use hydrogen fluoride in the SCAQMD. The manual identifies examples of potential causes as well as measures that may be taken to reduce the accidental-release risk.
Research Organization:
Radian Corp., Austin, TX (USA)
OSTI ID:
5885151
Report Number(s):
PB-87-227047/XAB; DCN-87-203-024-84-21
Country of Publication:
United States
Language:
English