Proposed testing protocols for commercial kitchen ventilation research
- Underwriters Labs., Inc., Northbrook, IL (USA)
Commercial kitchen ventilation systems significantly impact energy use and peak energy demand in foodservice establishments. However, the amount of ventilation exhaust required by different building codes and standards varies widely. Moreover, there is no industry-wide accepted testing procedure that quantifies and verifies exhaust capture and addresses the various types of cooking equipment used in commercial kitchens. This report provides a review of some requirements and practices which are currently in use. Proposals aimed at developing a more uniform approach to ventilation are discussed, including proposals for cooking and ventilation test protocols. Information obtained through a literature search and solicitation of information from cooking appliance and ventilation equipment manufacturers supports the conclusion that additional research and testing is needed to develop methods to establish ventilation requirements of commercial cooking equipment. Based on information gathered, and a meeting with industry representatives, draft test protocols were developed. The proposed protocols call for separate testing of cooking equipment and exhaust hoods. Tests of cooking equipment would be intended to characterize the effluent produced by specific equipment and cooking processes, and to facilitate equipment categorization with respect to cooking surface temperature and effluent generation rates. Using this information on cooking equipment, ventilation hoods would be tested to develop test procedures to determine ventilation requirements for specific hood and cooking equipment combinations. 12 refs., 7 tabs.
- Research Organization:
- Electric Power Research Inst., Palo Alto, CA (USA); Underwriters Labs., Inc., Northbrook, IL (USA)
- Sponsoring Organization:
- EPRI; Electric Power Research Inst., Palo Alto, CA (USA)
- OSTI ID:
- 5884846
- Report Number(s):
- EPRI-CU-7210
- Country of Publication:
- United States
- Language:
- English
Similar Records
Impact of reduced exhaust and ventilation rates at ``no-load`` cooking conditions in a commercial kitchen during winter operation
Estimating the energy-saving benefit of reduced-flow and/or multi-speed commercial kitchen ventilation systems
Related Subjects
APPLIANCES
VENTILATION
EXHAUST SYSTEMS
TESTING
COMMERCIAL BUILDINGS
COMMERCIAL SECTOR
ENERGY CONSERVATION
FOOD INDUSTRY
BUILDINGS
INDUSTRY
320303* - Energy Conservation
Consumption
& Utilization- Industrial & Agricultural Processes- Equipment & Processes
320106 - Energy Conservation
Consumption
& Utilization- Building Equipment- (1987-)