Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Sizing/calculating 50 to 200 horsepower individual well compressors

Book ·
OSTI ID:5871987

A sizing/calculating method for 50 to 200 hp individual well compressors is presented. Sizing calculations are made to illustrate the method for both rotary sliding vane and reciprocating compressors. The method requires knowledge of the specific gravity of the gas to be compressed, the K value of the gas, gas volume, gas inlet temperature, gas inlet and discharge pressure, and site elevation. After determining the K value of gas, the total ratio of compression is determined. Then, the theoretical discharge temperature is calculated to see if single stage compression is acceptable. An equation or published flow chart is used to find the estimated compressor horsepower. Then, the actual cubic feet per minute at inlet conditions of pressure and temperature is calculated. These results are then used to determine the approximate compressor cylinder displacement required to handle the calculated actual cubic feet per minute. Finally, the displacement and horsepower figures are used to specify appropriate equipment.

OSTI ID:
5871987
Country of Publication:
United States
Language:
English

Similar Records

Compressor inlet guide vanes
Journal Article · Wed Dec 09 23:00:00 EST 1981 · Plant Eng.; (United States) · OSTI ID:5124510

Gas compressor design program
Journal Article · Wed May 01 00:00:00 EDT 1991 · SPE Computer Applications (Society of Petroleum Engineers); (United States) · OSTI ID:5518444

P-V diagram simulation: a new approach to modeling reciprocating compressor performance
Conference · Sat Oct 01 00:00:00 EDT 1983 · Soc. Pet. Eng. AIME, Pap.; (United States) · OSTI ID:5289573