Switching losses in a GTO inverter for induction heating
Journal Article
·
· IEEE Transactions on Power Electronics (Institute of Electrical and Electronics Engineers); (USA)
- Inst. for Power Electronics and Electrical Drives, Aachen Univ. of Technology, Jagerstrasse 17/19, 5100 Aachen (DE)
In a parallel resonant inverter using gate- turn-off thyristors (GTO's), the turn-off losses can be reduced by gate-assisted turnoff technique, while turn-on losses contribute significantly to the total switching losses. For optimum operation of the GTO, the total switching losses have to be minimum. On the basis of loss measurement, an optimum mode of operation is suggested.
- OSTI ID:
- 5867296
- Journal Information:
- IEEE Transactions on Power Electronics (Institute of Electrical and Electronics Engineers); (USA), Journal Name: IEEE Transactions on Power Electronics (Institute of Electrical and Electronics Engineers); (USA) Vol. 6:1; ISSN 0885-8993; ISSN ITPEE
- Country of Publication:
- United States
- Language:
- English
Similar Records
A new inverter topology using GTO commutation
Advanced static compensation using a multilevel GTO thyristor inverter
Switch-mode var compensator with minimized switching losses and energy storage elements
Conference
·
Mon Aug 01 00:00:00 EDT 1983
· Proc., Intersoc. Energy Convers. Eng. Conf.; (United States)
·
OSTI ID:5363952
Advanced static compensation using a multilevel GTO thyristor inverter
Journal Article
·
Fri Mar 31 23:00:00 EST 1995
· IEEE Transactions on Power Delivery
·
OSTI ID:64417
Switch-mode var compensator with minimized switching losses and energy storage elements
Journal Article
·
Wed Jan 31 23:00:00 EST 1990
· IEEE Transactions on Power Systems (Institute of Electrical and Electronics Engineers); (USA)
·
OSTI ID:6927684