Sensitivity study of poisson corruption in tomographic measurements for air-water flows

Conference · · Transactions of the American Nuclear Society; (United States)
OSTI ID:5861804
 [1];  [2]
  1. Fraunhofer Institute for Nondestructive Testing, Saarbrucken (Germany)
  2. Indian Institute of Technology, Kanpur (India)
An application of computerized tomography (CT) for measuring void fraction profiles in two-phase air-water flows was reported earlier. Those attempts involved some special radial methods for tomographic reconstruction and the popular convolution backprojection (CBP) method. The CBP method is capable of reconstructing void profiles for nonsymmetric flows also. In this paper, we investigate the effect of corrupted CT data for gamma-ray sources and aCBP algorithm. The corruption in such a case is due to the statistical (Poisson) nature of the source.