Velocity profiles of granules in moving bed filters for flue gas cleanup
Conference
·
OSTI ID:585395
- National Central Univ., Chung-Li (Taiwan, Province of China)
- National Taiwan Univ., Taipei (Taiwan, Province of China); and others
The velocity fields in three symmetric and two asymmetric louver-walled moving bed systems are studied experimentally. The results indicate that the velocity profiles of filter granules are influenced by the louver geometry. When the louver angle is small, the velocity profile of filter granules is close to plug flow. When the angle of louvers is large, the quasi-stagnant zones exist alone the louver walls. The velocity profiles are less uniform with faster flowing core in the central part of filter bed. The refreshing rate of filter granules can be very low for the asymmetric louvered system. The kinematic model for predicting the granule velocity distribution is also used for analyzing the three symmetric louver geometries.
- Research Organization:
- Coal and Slurry Technology Association, Washington, DC (United States)
- OSTI ID:
- 585395
- Report Number(s):
- CONF-980309--PROC.
- Country of Publication:
- United States
- Language:
- English
Similar Records
Velocity profiles of granules in moving bed filters for flue gas cleanup
Stagnant zones in granular moving bed filters for flue gas cleanup
Stagnant zones in granular moving bed filters for flue gas cleanup
Conference
·
Wed Jul 01 00:00:00 EDT 1998
·
OSTI ID:20012983
Stagnant zones in granular moving bed filters for flue gas cleanup
Conference
·
Tue Mar 31 23:00:00 EST 1998
·
OSTI ID:585401
Stagnant zones in granular moving bed filters for flue gas cleanup
Conference
·
Wed Jul 01 00:00:00 EDT 1998
·
OSTI ID:20012986