A further development of the fluorescent gated gas scintillation proportional counter
Journal Article
·
· IEEE Trans. Nucl. Sci.; (United States)
Recent results from a K gated gas scintillation proportional counter filled with a Xenon/Helium mixture to a pressure of about 3 bar have already shown that a background rejection efficiency in excess of 99.3% can be achieved in the energy range 35-100 keV. In addition the application of the technique of fluorescent gating also provides energy resolutions below 3% at about 60 keV. Experimental results are presented for a gas scintillation counter filled with a Krypton/Xenon mixture which, through the use of the Krypton K fluorescent gate, enables a high background rejection and improved energy resolution, for the energy range above 14 keV, to be achieved.
- Research Organization:
- Space Science Department of the European Space Agency, European Space Research and Technology Centre, Noordwijk
- OSTI ID:
- 5852222
- Journal Information:
- IEEE Trans. Nucl. Sci.; (United States), Journal Name: IEEE Trans. Nucl. Sci.; (United States) Vol. 30:1; ISSN IETNA
- Country of Publication:
- United States
- Language:
- English
Similar Records
An integrated photosensor readout for gas proportional scintillation counters
Application of the digital pulse processing techniques to gas proportional scintillation counters
Recent progress in the development of a gas scintillation proportional counter for x-ray astronomy
Conference
·
Mon Dec 30 23:00:00 EST 1996
·
OSTI ID:513084
Application of the digital pulse processing techniques to gas proportional scintillation counters
Conference
·
Mon Dec 30 23:00:00 EST 1996
·
OSTI ID:513085
Recent progress in the development of a gas scintillation proportional counter for x-ray astronomy
Conference
·
Mon Jan 31 23:00:00 EST 1977
· IEEE Trans. Nucl. Sci.; (United States)
·
OSTI ID:7213108
Related Subjects
440101* -- Radiation Instrumentation-- General Detectors or Monitors & Radiometric Instruments
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
DATA
EFFICIENCY
ELEMENTS
ENERGY RANGE
ENERGY RESOLUTION
EXPERIMENTAL DATA
FLUIDS
FLUORESCENCE
GAS SCINTILLATION DETECTORS
GASES
HELIUM
INFORMATION
KEV RANGE
KEV RANGE 10-100
KRYPTON
LUMINESCENCE
MEASURING INSTRUMENTS
NONMETALS
NUMERICAL DATA
PROPORTIONAL COUNTERS
RADIATION DETECTORS
RARE GASES
RESOLUTION
SCINTILLATION COUNTERS
XENON
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
DATA
EFFICIENCY
ELEMENTS
ENERGY RANGE
ENERGY RESOLUTION
EXPERIMENTAL DATA
FLUIDS
FLUORESCENCE
GAS SCINTILLATION DETECTORS
GASES
HELIUM
INFORMATION
KEV RANGE
KEV RANGE 10-100
KRYPTON
LUMINESCENCE
MEASURING INSTRUMENTS
NONMETALS
NUMERICAL DATA
PROPORTIONAL COUNTERS
RADIATION DETECTORS
RARE GASES
RESOLUTION
SCINTILLATION COUNTERS
XENON