The system consisted of a multiple-compartment ion-exchange (MCIX) elution column with a continuous flow of solution, except for short periods when the resin increments were withdrawn. The exchange of uranyl carbonate from the mill loaded strong base resin with an eluant composed of 1.0 M Na/sub 2/CO/sub 3/ plus 1.0 M NH/sub 4/HCO/sub 3/ was studied. The effects of solution flow rate, aqueous-to-resin flow ratio, column diameter, compartment height, initial resin concentration, and column length were examined. The experimental data indicate that for the eluant examined a resin residence time of 240 minutes is necessary to attain 90-percent elution efficiency. Also provided is a technique for sizing an elution MCIX column form pilot plant experimental data. 18 figures, 2 tables.

Research Organization:
Bureau of Mines, Salt Lake City, UT (USA). Salt Lake City Metallurgy Research Center
OSTI ID:
5840739
Report Number(s):
BM-RI-8370
Country of Publication:
United States
Language:
English