Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

The gain characteristics of microchannel plates for x-ray photon counting

Journal Article · · IEEE Trans. Nucl. Sci.; (United States)
A theoretical and experimental study is reported of the gain of microchannel plate (MCP) electron multipliers under conditions of output charge saturation. Theoretical calculations, assuming a wall charge saturation mechanism, are used to interpret peak gain and pulse height distribution FWHM data obtained with a number of chevron MCP multipliers. A curved surface MCP intended for use with grazing incidence X-ray optics is described. The effects of an inter-plate voltage are described. Limiting pulse height FWHMs around 30% have been obtained. The properties of straight channel chevrons and single curved channel MCPs are briefly compared.
Research Organization:
X-ray Astronomy Group Physics Department, University of Leicester, Leicester LE1 7RH
OSTI ID:
5839530
Journal Information:
IEEE Trans. Nucl. Sci.; (United States), Journal Name: IEEE Trans. Nucl. Sci.; (United States) Vol. 30:1; ISSN IETNA
Country of Publication:
United States
Language:
English