10 MWe Solar Thermal Central Receiver Pilot Plant: solar facilities design integration. Receiver tower structural analysis: construction package No. 5A (RADL Item 7-21)

Technical Report ·
OSTI ID:5837449
This document is provided in support of the Receiver Tower Structural Steel Construction Package No. 5A and includes the design analyses, procedures, computer printouts, mode shapes, input requirements, and the design codes/guides used to perform the analysis. The analysis included herein was made for both the receiver tower primary structure and the receiver unit core support structure in so far as primary structural members for the overall wind and seismic loading consideration.
Research Organization:
Stearns-Roger Corp., Denver, CO (USA)
DOE Contract Number:
AC03-79SF10499
OSTI ID:
5837449
Report Number(s):
DOE/SF/10499-T94; STMPO-179; SAN-0499-45; MDC-G-8267; ON: DE86000664
Country of Publication:
United States
Language:
English