Combined cold compressor/ejector helium-refrigerator cycle

Conference ·
OSTI ID:5832403

A series of tests is reported as part of the program to demonstrate the feasibility of cold compressors as related to a large refrigerator. The use of a cold compressor in series with an ejector has been shown as an effective way to produce low pressure in a helium refrigeration system. Compared with a system which uses an ejector alone, the combined cold compressor and ejector system produces a lower temperature on the same load or more cooling at the same temperature. (LEW)