skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Higher-harmonics suppressor for soft x rays

Journal Article · · Rev. Sci. Instrum.; (United States)
DOI:https://doi.org/10.1063/1.1140829· OSTI ID:5831857

We have developed an apparatus for suppressing higher harmonics contained in the soft x-ray output beam of grazing-incidence grating monochromators. It consists of eight pairs of total-reflection mirrors. Each pair serves as a low-pass filter with the cutoff energy different from one another. The eight pairs are designed to cover an energy range of 80--1600 eV with an efficiency of harmonic suppression better than 97%, while transmitting more than 50% of the fundamental photons. We have tested its preliminary performance on the soft x-ray beamline BL-8A at the Photon Factory. We present the observed transmission efficiencies and the effects of the harmonic suppressor on measurements of reflectivity and fluorescence spectra.

Research Organization:
Advanced Research Laboratory, Hitachi, Ltd., Kokubunji, Tokyo 185, Japan (JP)
OSTI ID:
5831857
Journal Information:
Rev. Sci. Instrum.; (United States), Vol. 60:7
Country of Publication:
United States
Language:
English