Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Voltage-pulse generator for electron gun

Journal Article · · Instrum. Exp. Tech. (Engl. Transl.); (United States)
OSTI ID:5830402

A voltage-pulse generator with combined capacitive and inductive storage devices of an electron gun is described. The current interrupter is a hydrogen thyratron (TGI1-100/8, TGI1-500/16, or TGI1-1000/25) installed in a short magnetic lens. The current interruption time of the thyratrons is 100-300 nsec. When the capacitive storage device is charged to 1 kV, a voltage pulse with an amplitude of 25 kV is obtained at the load.

Research Organization:
Joint Institute for Nuclear Research, Dubna, USSR
OSTI ID:
5830402
Journal Information:
Instrum. Exp. Tech. (Engl. Transl.); (United States), Journal Name: Instrum. Exp. Tech. (Engl. Transl.); (United States) Vol. 30:2; ISSN INETA
Country of Publication:
United States
Language:
English

Similar Records

High-voltage short-fall pulse generator
Journal Article · Tue Jul 01 00:00:00 EDT 1986 · Instrum. Exp. Tech. (Engl. Transl.); (United States) · OSTI ID:5224541

High-voltage pulse generator for wire spark chambers
Journal Article · Wed Dec 31 23:00:00 EST 1975 · Instrum. Exp. Tech. (USSR) (Engl. Transl.); (United States) · OSTI ID:7291391

Thyratron-choke switch for high-current nanosecond pulses