Use of MAG-1 spectacles with positive- and negative-pressure respirators

Technical Report ·
OSTI ID:5828790

Results of testing conducted at Los Alamos National Laboratory, Personnel Protection Studies Section, using MAG-1 spectacles in conjunction with positive- and negative-pressure full-facepiece respirators, are reported. The purpose of the three-phase study was to determine if the specially constructed strap of the MAG-1s affected the protection factors (PFs) of the respirators or the cylinder life of selected self-contained breathing apparatus (SCBA). The following respirators were tested with the MAG-1s: (1) Phases I and II, positive-pressure full facepiece: Presur-Pak II SCBA (pressure-demand) Scottoramic facepiece, MSA 401 Air Mask Ultravue facepiece (medium), Survivair pressure-demand SCBA/silicone full facepiece, MSA powered air-purifying respirator/Ultravue facepiece (medium); and (2) Phase III, negative-pressure full facepiece: MSA Ultravue (small, medium, large), MSA Ultra-twin (small, medium, large), Norton Series 7600 (one size only). Statistical analysis and review of the test data from Phases I and II indicated little, if any, variation with and without the MAG-1s with most protection factors greater than 10,000. Test data also indicated little, if any, difference in the cylinder life with and without the MAG-1s, except the Scott Presur-Pak II SCBA used with the Scottoramic facepiece. Statistical analysis of the quantitative fit test data indicated no difference in PFs for the negative-pressure devices for the Ultravue negative-pressure respirator, but a significance at the 0.05 and 0.01 levels for the Ultra-twin and Norton full facepieces, respectively.

Research Organization:
Los Alamos National Lab., NM (USA)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
5828790
Report Number(s):
NUREG/CR-3953; LA-10229-MS; ON: TI85010351
Country of Publication:
United States
Language:
English

Similar Records

Study of facepiece leakage of self-contained breathing apparatus by DOP man tests. Progress report, July 1, 1971--February 29, 1972
Technical Report · Fri Mar 31 23:00:00 EST 1972 · OSTI ID:6635135

Effect of facial hair on the face seal of negative-pressure respirators
Journal Article · Sat Dec 31 23:00:00 EST 1983 · Am. Ind. Hyg. Assoc. J.; (United States) · OSTI ID:6776824

Physiological response to ''pressure-demand'' respirator wear
Journal Article · Thu Jul 01 00:00:00 EDT 1982 · Am. Ind. Hyg. Assoc. J.; (United States) · OSTI ID:6419528