A low-pressure, short-term station blackout severe accident sequence has been analyzed using the MELCOR code, version 1.8.1, in a boiling water reactor (BWR)-4. This paper presents a sensitivity study evaluating the effect of several MELCOR input parameters on vessel failure time. Results using the MELCOR/CORBH package and the BWRSAR code are also presented and compared to the MELCOR results. These calculated vessel failure times are discussed, and a judgment is offered as to which is the most realistic.