Backflow in twin-screw-type multiphase pump
- Japan National Oil Corp., Chiba (Japan)
- Kyushu Univ. (Japan)
The performance of a twin-screw-type multiphase pump was investigated from the viewpoints of backflow in a gap along the twin-screw shafts and of scaleup parameters. Although both the backflow and the scaleup parameters have been recognized as important factors in developing multiphase pumps, they have not yet been clarified. The twin-screw pump was equipped with pressure sensors, set in the multiphase-test facility, and experimented with under various conditions to clarify the relationship between backflow rates and factors such as differential pressure, gas-void fractions (GVF`s), and the rotation speed of the shaft. A physical model was proposed with the empirical relationship of pressure distribution along the screw, and was successfully associated with scaleup parameters, such as the geometrical data of the twin-screw pump. Then it was used successfully to simulate the backflow in twin-screw pumps on relatively broad experimental conditions, judging from the comparison between the model and the experimental data.
- Sponsoring Organization:
- USDOE
- OSTI ID:
- 580835
- Journal Information:
- SPE Production and Facilities, Vol. 13, Issue 1; Other Information: PBD: Feb 1998