An experimental investigation into the performance of Class 1E electronic pressure transmitters exposed to environments within and beyond the design basis has been conducted. Emphasis was placed on determining the instruments' failure and degradation modes in separate and simultaneous environmental exposures. Five unaged ITT Barton Model 763 pressure transmitters were tested; each transmitter was exposed to a unique environment. The environments were (1) simulated Loss of Coolant Accident (LOCA) steam/chemical spray conditions alone, (2) temperature alone, (3) radiation alone, (4) simultaneous radiation and LOCA temperature (no steam) conditions, and (5) simultaneous radiation and simulated LOCA steam/chemical spray conditions. 23 refs., 33 figs., 8 tabs.

Research Organization:
Sandia National Labs., Albuquerque, NM (USA)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
5801810
Report Number(s):
NUREG/CR-3863; SAND-84-1264; ON: TI85012824
Country of Publication:
United States
Language:
English

Similar Records

Performance assessment of Class 1E pressure transmitters subjected to environmental stresses
Conference · Sat Dec 31 23:00:00 EST 1983 · OSTI ID:6028698

Implementation of French Bibloc 1E-pressure transmitters in PWRs (pressurized water reactor)
Conference · Tue Oct 31 23:00:00 EST 1989 · Transactions of the American Nuclear Society; (United States) · OSTI ID:5376291

Testing of nuclear qualified cables and pressure transmitters in simulated hydrogen deflagrations to determine survival margins and sensitivities
Technical Report · Sat Nov 30 23:00:00 EST 1985 · OSTI ID:6253396