Geothermal potential for commercial and industrial direct heat applications in Salida, Colorado. Final report

Technical Report ·
DOI:https://doi.org/10.2172/5801752· OSTI ID:5801752
The Salida Geothermal Prospect (Poncha Hot Springs) was evaluated for industrial and commercial direct heat applications at Salida, Colorado, which is located approximately five miles east of Poncha Hot Springs. Chaffee Geothermal, Ltd., holds the geothermal leases on the prospect and the right-of-way for the main pipeline to Salida. The Poncha Hot Springs are located at the intersection of two major structural trends, immediately between the Upper Arkansas graben and the Sangre de Cristo uplift. Prominent east-west faulting occurs at the actual location of the hot springs. Preliminary exploration indicates that 1600 gpm of geothermal fluid as hot as 250/sup 0/F is likely to be found at around 1500 feet in depth. The prospective existing endusers were estimated to require 5.02 x 10/sup 10/ Btu per year, but the total annual amount of geothermal energy available for existing and future endusers is 28.14 x 10/sup 10/ Btu. The engineering design for the study assumed that the 1600 gpm would be fully utilized. Some users would be cascaded and the spent fluid would be cooled and discharged to nearby rivers. The economic analysis assumes that two separate businesses, the energy producer and the energy distributor, are participants in the geothermal project. The producer would be an existing limited partnership, with Chaffee Geothermal, Ltd. as one of the partners; the distributor would be a new Colorado corporation without additional income sources. Economic evaluations were performed in full for four cases: the Base Case and three alternate scenarios. Alternate 1 assumes a three-year delay in realizing full production relative to the Base Case; Alternate 2 assumes that the geothermal reservoir is of a higher quality than is assumed for the Base Case; and Alternate 3 assumes a lower quality reservoir. 11 refs., 34 figs., 40 tabs.
Research Organization:
Chaffee Geothermal Ltd., Denver, CO (USA); Western Energy Planners Ltd., Aurora, CO (USA)
DOE Contract Number:
FC07-81ID12192
OSTI ID:
5801752
Report Number(s):
DOE/ID/12192-1; ON: DE84014797
Country of Publication:
United States
Language:
English

Similar Records

Engineering design for geothermal commerical and industrial direct heat applications in Salida, Colorado
Conference · Thu Oct 01 00:00:00 EDT 1981 · Trans. - Geotherm. Resour. Counc.; (United States) · OSTI ID:7097342

Binary generating units at Kelly Hot Springs, California
Technical Report · Wed Aug 01 00:00:00 EDT 1984 · OSTI ID:6545462

Binary power plant analysis
Journal Article · · Geo-Heat Cent. Q. Bull.; (United States) · OSTI ID:6979963