Inherent freeze protection for solar water heaters

Technical Report ·
DOI:https://doi.org/10.2172/5794081· OSTI ID:5794081
Research and development of a method for protection of a solar collector from freezing is described. The method is shown to be technically and economically feasible. A prototype water heating system using the inherent freeze protection method was successfully operated during the winter of 1980 to 1981.
Research Organization:
Jeter (Sheldon M.), Atlanta, GA (USA)
DOE Contract Number:
FG44-80R410114
OSTI ID:
5794081
Report Number(s):
DOE/R4/10114-T1; ON: DE84000392
Country of Publication:
United States
Language:
English

Similar Records

An inherently freeze protected solar water heater
Conference · Wed Jun 01 00:00:00 EDT 1983 · Proc. Annu. Meet. - Am. Sect. Int. Sol. Energy Soc.; (United States) · OSTI ID:5048552

100% freeze protection for thermosiphon solar water heaters
Technical Report · Wed Nov 30 23:00:00 EST 1983 · OSTI ID:6393232

Promising freeze protection alternatives in solar domestic hot water systems
Thesis/Dissertation · Tue Dec 31 23:00:00 EST 1996 · OSTI ID:578643