Cw dye laser system for Li beam spectroscopy in a tokamak

Conference ·
OSTI ID:5792202
The current density profile diagnostic system developed for the TEXT tokamak employs a cw dye laser system to induce fluorescence in a Li beam injected into a tokamak. This laser spectral and polarization modulation requirements not available in commerical systems. The required spectrum is a bandwidth of approximately 5 GHz at a wavelength of 667 nm. The intensity within the bandwidth should be as uniform as possible, i.e., a quasi-continuum within the 5 GHz bandwidth. The polarization of the laser must remain linear, but the plane of polarization must be rotated at a high frequency, 50 kHz. The details of the Li atomic spectrosocpy in a tokamak and the requirements of the diagnostic system that lead to these desired laser parameters will be addressed. The laser system and polarization modulator which have been developed will be discussed in detail, including both design and performance parameters. Possible improvements to enhance performance will also be addressed.
Research Organization:
GA Technologies, Inc., San Diego, CA (USA)
DOE Contract Number:
AC03-84ER53158
OSTI ID:
5792202
Report Number(s):
GA-A-18415; CONF-860324-24; ON: DE86010217
Country of Publication:
United States
Language:
English