Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

1984 NRC Branch annual report: Steam Generator Group Project

Technical Report ·
OSTI ID:5787128

Program objectives are to develop validated models, based on experimental data, for prediction of margins-to-failure under burst and collapse pressures of steam generator tubing found to be service-degraded by eddy current inservice inspection. This required the research contractor, Pacific Northwest Laboratory, to obtain, house and prepare an out-of-service degraded steam generator for a confirmatory research program. This research includes: (1) validation of current and developmental nondestructive examination techniques; (2) optimization of inservice inspection procedures, sampling plan and inspection period; (3) validation of tube integrity predictive models; (4) validation of stress corrosion cracking predictive models; (5) development/optimization of tube plugging criteria; and (6) evaluation of proposed chemical cleaning and decontamination processes/procedures with respect to near-term integrity and long-term effects on corrosion, degradation and safety.

Research Organization:
Pacific Northwest Labs., Richland, WA (USA)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
5787128
Report Number(s):
PNL-SA-13015; ON: TI85009435
Country of Publication:
United States
Language:
English