skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Mk22 out-of-specification fractional fuel tube ratios and indeterminate fuel and target tubes

Technical Report ·
OSTI ID:5780079

Fractional Fuel Tube Ratio is defined as the ratio of grams {sup 235}U/ft in each outer fuel tube to the total g {sup 235}U/ft in each assembly. The ratios for the affected assemblies range from 0.518 to 0.520 with the minimum allowable specified as 0.521. Eight out-of-specification assemblies and 95 indeterminate assemblies were discovered in the P-11, K-14, and L-4 MK22 reactor charges. The eight out-of-spec assemblies in the P-11 charge did not meet the specification set forth in RTM-4432, Mark 22 Charge Specifications, Revision 6. The indeterminate assemblies either did not have a process history record to confirm the target or fuel content on the matchlist, or the process history record did not agree with the matchlist values. Twenty-five assemblies (8 out-of-spec and 17 indeterminate) in the P-11 cycle were charged to the reactor between 9/9/88 and 9/11/88. The indeterminate assemblies in the K-14 and L-4 reactor charges were discovered after shipment but before being charged to K or L Reactors. The out-of-specification assemblies will be irradiated with appropriate operating limits and the indeterminate target and fuel tubes will be replaced prior to reactor startup.

Research Organization:
Westinghouse Savannah River Co., Aiken, SC (United States)
Sponsoring Organization:
USDOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
5780079
Report Number(s):
RER-P-1853; RER-K-2228; RER-L-789; ON: DE92009896
Country of Publication:
United States
Language:
English