Electrolytic gettering of tritium from air

Conference ·
OSTI ID:5777412
We have removed 90% of 1 part-per-million tritium gas in air of 25% to 35% humidity by the dc electrical action of the solid proton electrolyte hydrogen uranyl phosphate (HUP). Gettering takes 5 to 24 hours for a 1 cm/sup 2/ HUP disc at 2 to 4 V in a static, 1200 cc gas volume. Hydrogen gas may be used to flush captured tritium through the HUP. Liquid water leaches out the tritium but water vapor is ineffective. This technique promises an alternative to the conventional catalyst/zeolite method.