HEMP-induced transients in electric power substations
- BDM International, Inc., Albuquerque, NM (United States)
A nuclear detonation in or above the earth's atmosphere produces an intense electromagnetic pulse (EMP). A large portion of the EMP electromagnetic energy is within the RF spectrum. A detonation at high altitudes above 40 km produces an EMP called high-altitude EMP (HEMP). HEMP is a steep-front short duration transient with a rise time on the order of a few nanoseconds which decays to near zero in less than a microsecond. A single high-altitude burst can subject much of the continental United States to intense HEMP electric fields on the order of tens of kilovolts per meter. The intense transient HEMP will induce fast transients in high-voltage transmission lines and bus structures, instrumentation cables, and control wires in power transmission and distribution (T D) substations. A system of traveling wave coupling models for a 500 kV substation, including models for the high voltage primary bus, components (circuit breakers, disconnect switches, power transformers, and current and voltage instrument transformers), low voltage control wiring circuits, and a number of conducted and radiated interference coupling modes, had been developed earlier by EPRI. These EPRI served as the baseline for the present HEMP coupling investigations. The HEMP effects on protective relays were assessed for a nominal HEMP environment using several new field coupling models merged with the switching transient data. It is found that a representative solid state relay is unlikely to be damaged or to misoperate by the nominal HEMP threat with a peak field strength of 50 kV/m. However, it is possible for both DC control wires to flash over to ground simultaneously, causing fuses to blow and placing the relay in an inoperative state.
- Research Organization:
- Oak Ridge National Lab., TN (United States); BDM International, Inc., Albuquerque, NM (United States)
- Sponsoring Organization:
- DOE; USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 5776239
- Report Number(s):
- ORNL/Sub-88-SC863; ON: DE92007797
- Country of Publication:
- United States
- Language:
- English
Similar Records
HEMP Testing of Substation Yard Circuit Breaker Control and Protective Relay Circuits
HEMP interaction with an electric power distribution circuit. Final report
Related Subjects
240200* -- Power System Networks
Transmission & Distribution-- (1990-)
45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEFENSE
450200 -- Military Technology
Weaponry
& National Defense-- Nuclear Explosions & Explosives
CIRCUIT BREAKERS
DOCUMENT TYPES
ELECTRIC MEASURING INSTRUMENTS
ELECTRICAL EQUIPMENT
ELECTRICAL TRANSIENTS
ELECTROMAGNETIC PULSES
ELECTROMAGNETIC RADIATION
ELECTRONIC CIRCUITS
EQUIPMENT
EQUIPMENT PROTECTION DEVICES
EXPLOSIONS
LEVELS
MEASURING INSTRUMENTS
NUCLEAR EXPLOSIONS
PHYSICAL RADIATION EFFECTS
POWER SUBSTATIONS
POWER TRANSMISSION LINES
PROGRESS REPORT
PULSES
RADIATION EFFECTS
RADIATIONS
RELAYS
SWITCHES
TRANSFORMERS
TRANSIENTS
VOLTAGE DROP