The AGS Booster low frequency rf system
Conference
·
OSTI ID:5773313
An rf system has been designed to accelerate all the desired species of ions up to Gold, which will be available at {beta} = 0.048. The system will run on different harmonic numbers (h). It will start from h = 12 at injection and jump to h = 3 during the cycle. The beam will then be transferred to the high frequency RF system that will bring it to the extraction energy. The low frequency system consists of two single gap cavities that sweep from 0.6 to 2.4 MHz, with gap voltages up to 17 kV. The cavities are loaded with TDK SY7 high permeability ferrite rings. Tuning will be accomplished by changing the permeability of the ferrite with dc bias currents as high as 200 A flowing in two figure of eight'' windings. The cavity will be driven by a 200 kW push-pull tetrode power amplifier, which will be driven by remotely located solid state drivers. 5 refs., 2 figs., 2 tabs.
- Research Organization:
- Brookhaven National Lab., Upton, NY (USA)
- Sponsoring Organization:
- DOE; USDOE, Washington, DC (USA)
- DOE Contract Number:
- AC02-76CH00016
- OSTI ID:
- 5773313
- Report Number(s):
- BNL-45423; CONF-910505--216; ON: DE91013796
- Country of Publication:
- United States
- Language:
- English
Similar Records
Test results of the AGS Booster low frequency RF system
Test results of the AGS Booster low frequency RF system
A high level, low frequency rf system for the acceleration of light ions in the AGS
Conference
·
Tue Jun 01 00:00:00 EDT 1993
·
OSTI ID:10160145
Test results of the AGS Booster low frequency RF system
Conference
·
Thu Dec 31 23:00:00 EST 1992
·
OSTI ID:7368563
A high level, low frequency rf system for the acceleration of light ions in the AGS
Conference
·
Wed Dec 31 23:00:00 EST 1986
·
OSTI ID:6643074