Life test of a nickel cadmium battery with a protection/reconditioning circuit
Technical Report
·
OSTI ID:5762084
Results are discussed for a Ni-Cd battery test over a period of 8 years, 2 months and 44,213 simulated low Earth orbits. The battery cells were protected against overdischarge and reversal at discharge rates up to 25 amperes (1.25C) by a battery protection and reconditioning circuit. The circuit performed flawlessly during the test, and proved its value, both as a battery reconditioner and a cell protection device. Battery cell failures are also discussed. The test demonstrated the viability of using Ni-Cd batteries at depth-of-discharge up to 25 percent for over 5 years in a low Earth orbit.
- Research Organization:
- National Aeronautics and Space Administration, Huntsville, AL (USA). George C. Marshall Space Flight Center
- OSTI ID:
- 5762084
- Report Number(s):
- NASA-TP-1873
- Country of Publication:
- United States
- Language:
- English
Similar Records
Nickel--cadmium battery reconditioning circuit. [24-cell, 20-Ah batteries]
Method and apparatus for reconditioning nickel--cadmium batteries. [Patent application]
Deep discharge reconditioning and shorted storage of batteries. Final Report