Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Review of the analyses of the Doppler-effect measurements in SEFOR (Southwest Experimental Fast Oxide Reactor)

Technical Report ·
DOI:https://doi.org/10.2172/5747146· OSTI ID:5747146
The SEFOR experimental results and the three original analyses are reviewed and discussed. The emphasis of the review is placed on aspects that are pertinent to a possible modern re-analysis of the experimental results. Looking at the analysis results in terms of zero and first order effects shows that the zero order effects, the Doppler constant of the two SEFOR cores, are obtained by the three analyses in satisfactory agreement. But the first order effects, but temperature variation of this Doppler-constant quantity, cannot be determined with any informative accuracy. Since this is likely due to limitations in the experiments, a re-analysis - except for methodological reasons - does not appear to be fruitful. 17 refs., 8 figs., 7 tabs.
Research Organization:
Argonne National Lab., IL (USA)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
5747146
Report Number(s):
ANL-87-42; ON: DE88004142
Country of Publication:
United States
Language:
English