30-kV proton injector for PIGMI

Conference ·
OSTI ID:5739404
A 30-kV proton injector designed for matching a 31-mA proton beam into the radio-frequency quadrupole (RFQ) section of the PIGMI accelerator has been constructed and tested. This injector uses a small efficient duoplasmatron ion source and a single-gap extraction system for creating a convergent ion beam, and a three-element unipotential einzel lens for focusing the ion beam into the RFQ. A description of this prototype injector is presented, along with the experimental data obtained during the testing of this system.
Research Organization:
Los Alamos National Lab., NM (USA)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
5739404
Report Number(s):
LA-UR-81-3053; CONF-811083-22; ON: DE82006125
Country of Publication:
United States
Language:
English