Site handbook: data acquisition system information, passive solar retrofit Automobile Maintenance Facility, City of Philadelphia

Technical Report ·
OSTI ID:5734617
Data were collected at the City of Philadelphia's Auto Maintenance Facility using an Aeoloan Kinetics PDL-24 data acquisition system. Instantaneous data readings were recorded each 15 seconds by the microprocessor. These channel readings were then averaged to produce hourly values which were then stored on an audio cassette. The energy saving strategies include: styrofoam and concrete roof coverings; weatherstripping; replacement of north windows with combination insulation and view glazing; PVC strips between heated and unheated areas; gas fired radiant heaters at individual work stations; reduction of the number of light fixtures; and the installation of retrofit window units for radiant solar heating, daylighting, ventilation, glare control and vandalism protection.
Research Organization:
Architectural Energy Corp., Westminster, CO (USA)
DOE Contract Number:
AC02-82CE30749
OSTI ID:
5734617
Report Number(s):
DOE/CE/30749-T12; ON: DE85010904
Country of Publication:
United States
Language:
English