Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

On-line gamma-ray data acquisition at the Power Burst Facility

Conference ·
OSTI ID:5734320
The PBF (Power Burst Facility) Fission Product Detection System (FPDS) incorporates four on-line gamma ray spectrometers controlled by operators one kilometer distant. The FPDS is uniquely designed to monitor the high fission product concentrations generated when reactor fuel rods are severely damaged. Through the use of variable collimators, fast analog electronics, a pulser subsystem, and a carefully designed shield, this system has monitored samples with dose rate readings greater than 900 R/h. The spectral data acquired by the FPDS have provided fission product release and transport behavior information not previously available from off-line or gross radiation monitoring methods.
Research Organization:
Idaho National Engineering Lab., Idaho Falls (USA)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
5734320
Report Number(s):
EGG-M-08985; CONF-850533-5; ON: DE85011957
Country of Publication:
United States
Language:
English