Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Lanthanum hexaboride tapered filament in a plasma source

Journal Article · · Rev. Sci. Instrum.; (United States)
DOI:https://doi.org/10.1063/1.1138198· OSTI ID:5733741

A directly heated lanthanum hexaboride tapered filament has been tested in a plasma generator. A uniform temperature distribution at 1820 K has been achieved. The heating and cooling power calculated from measured quantities are balanced. A maximum arc current of 80 A was obtained, limited only by the power supply and plasma generator. The corresponding hydrogen ion current density was 0.6 A/cm/sup 2/ when the arc voltage was 80 V and the filament heater current was about 5 A. The filament was capable of emitting 100 A of current at an operating temperature of 1900 K. The estimated lifetime for this filament is 900 h.

Research Organization:
Lawrence Berkeley Laboratory, University of California, Berkeley, California 94720
DOE Contract Number:
AC03-76SF00098
OSTI ID:
5733741
Journal Information:
Rev. Sci. Instrum.; (United States), Journal Name: Rev. Sci. Instrum.; (United States) Vol. 56:5; ISSN RSINA
Country of Publication:
United States
Language:
English