Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Microcomputer aided calculations of parameters for spray dryer operation

Conference ·
OSTI ID:5731399
This paper provides a series of practical microcomputer programs that can be used as a tool by engineers and researchers working with spray dryers for combustion process effluent control. The microcomputer programs calculate flue gas composition (CO/sub 2/, N/sub 2/, O/sub 2/, H/sub 2/O, and SO/sub 2/) from the composition of the fuel. The residence time of the flue gas in a spray dryer can be estimated, and using values provided by the user for the flow of water and absorbent slurry in the spray dryer, the program recalculates the flue gas composition and heat capacity at the exit of the spray dryer without accounting for any SO/sub 2/ removal that could occur in the spray dryer. From these values and the system pressure, the dew point and flue gas temperature at the spray dryer exit are calculated, providing the approach to saturation resulting from this choice of operating parameters. This computer code would enable a process engineer to quickly evaluate effects of important process parameters, such as flue gas temperature at the inlet to the spray dryer, atomizer water feed rate, and absorbent slurry concentration and feed rate, on the operation of a spray dryer.
Research Organization:
USDOE Pittsburgh Energy Technology Center, PA
OSTI ID:
5731399
Report Number(s):
CONF-850612-4; ON: DE85013468
Country of Publication:
United States
Language:
English