Empirical correlation of residual gamma radiation resulting from operation of the Health Physics Research Reactor

Technical Report ·
DOI:https://doi.org/10.2172/5730656· OSTI ID:5730656
An empirical equation has been developed which gives gamma dose equivalent rate as a function of time, distance, and fission yield after a pulsed operation of Oak Ridge National Laboratory's (ORNL) unshielded Health Physics Research Reactor (HPRR). A related expression which is applicable to steady-state reactor operation has been mathematically derived from the aforementioned empirical equation. The two relations can be used to predict the gamma dose equivalent rate to within 25% for times between 1 minute and 90 minutes after reactor shutdown. Similar agreement is expected for up to several days. In most cases the relations are expected to overestimate the gamma dose equivalent rate. 5 refs., 4 figs., 1 tab.
Research Organization:
Oak Ridge National Lab., TN (USA)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Nuclear Criticality Safety Program (NCSP)
DOE Contract Number:
AC05-84OR21400
OSTI ID:
5730656
Report Number(s):
ORNL-6144; ON: DE85012075
Country of Publication:
United States