Thermal energy storage demonstration unit for Vuilleumier cryogenic cooler (Hi-Cap unit number 2). Addendum. Final report, 1 February-31 July 1978
Technical Report
·
OSTI ID:5712943
A second thermal energy unit for the High Capacity (Hi-Cap) Vuilleumier Cryogenic Cooler was built and tested. Incorporated into this unit were several design improvements consisting of the addition of a conduction heat transfer barrier between the radiation heat shield insulation and the mounting flange, modification of the O-ring seal of the insulation container, moving the hot cylinder-mounting flange interface, and changing the instrumentation. All design changes proved to be beneficial. The thermal losses that can be attributed to heat transfer through the insulation were lowered by about 8W from those of the first Hi-Cap TES unit. The inclusion of the terminal ring into the flange and separating the flange from the hot cylinder resulted in a substantial cost saving in material and machining of the components. The three, 1/16-inch diameter Inconel sheathed K calibration thermocouples performed consistently during the entire test period. The prime concern has been the discharge characteristic of the TES unit. Test data evaluation has indicated that the charging characteristic of the TES unit should be further investigated to obtain necessary information which will be required for the integration of the TES unit with the cryogenic cooler.
- Research Organization:
- Xerox Electro-Optical Systems, Pasadena, CA (USA)
- OSTI ID:
- 5712943
- Report Number(s):
- AD-A-068816
- Country of Publication:
- United States
- Language:
- English
Similar Records
Thermal energy storage demonstration unit for Vuilleumier cryogenic cooler. Final report, 15 October 1976--31 July 1977
Thermal energy storage evaluation and life testing. Interim report May-Oct 81
Thermal energy storage demonstration unit for Vuilleumier cryogenic cooler. Interim report 2 Jun 75--31 Aug 76
Technical Report
·
Sat Oct 01 00:00:00 EDT 1977
·
OSTI ID:6451675
Thermal energy storage evaluation and life testing. Interim report May-Oct 81
Technical Report
·
Fri Dec 31 23:00:00 EST 1982
·
OSTI ID:5567515
Thermal energy storage demonstration unit for Vuilleumier cryogenic cooler. Interim report 2 Jun 75--31 Aug 76
Technical Report
·
Mon Jan 31 23:00:00 EST 1977
·
OSTI ID:7092278
Related Subjects
25 ENERGY STORAGE
250600* -- Energy Storage-- Thermal
CONVERSION
COOLING
CRYOGENICS
DESIGN
ELECTRONIC EQUIPMENT
ENERGY CONVERSION
ENERGY STORAGE
ENERGY TRANSFER
EQUIPMENT
HEAT TRANSFER
PHASE STUDIES
POWER PLANTS
POWER SUPPLIES
SPACE VEHICLES
STORAGE
THERMAL ENERGY STORAGE EQUIPMENT
THERMAL INSULATION
THERMAL POWER PLANTS
THERMODYNAMIC CYCLES
VUILLEUMIER CYCLE
250600* -- Energy Storage-- Thermal
CONVERSION
COOLING
CRYOGENICS
DESIGN
ELECTRONIC EQUIPMENT
ENERGY CONVERSION
ENERGY STORAGE
ENERGY TRANSFER
EQUIPMENT
HEAT TRANSFER
PHASE STUDIES
POWER PLANTS
POWER SUPPLIES
SPACE VEHICLES
STORAGE
THERMAL ENERGY STORAGE EQUIPMENT
THERMAL INSULATION
THERMAL POWER PLANTS
THERMODYNAMIC CYCLES
VUILLEUMIER CYCLE