Comparison of the results of several heat transfer computer codes when applied to a hypothetical nuclear waste repository
A direct comparison of transient thermal calculations was made with the heat transfer codes HEATING5, THAC-SIP-3D, ADINAT, SINDA, TRUMP, and TRANCO for a hypothetical nuclear waste repository. With the exception of TRUMP and SINDA (actually closer to the earlier CINDA3G version), the other codes agreed to within +-5% for the temperature rises as a function of time. The TRUMP results agreed within +-5% up to about 50 years, where the maximum temperature occurs, and then began an oscillary behavior with up to 25% deviations at longer times. This could have resulted from time steps that were too large or from some unknown system problems. The available version of the SINDA code was not compatible with the IBM compiler without using an alternative method for handling a variable thermal conductivity. The results were about 40% low, but a reasonable agreement was obtained by assuming a uniform thermal conductivity; however, a programming error was later discovered in the alternative method. Some work is required on the IBM version to make it compatible with the system and still use the recommended method of handling variable thermal conductivity. TRANCO can only be run as a 2-D model, and TRUMP and CINDA apparently required longer running times and did not agree in the 2-D case; therefore, only HEATING5, THAC-SIP-3D, and ADINAT were used for the 3-D model calculations. The codes agreed within +-5%; at distances of about 1 ft from the waste canister edge, temperature rises were also close to that predicted by the 3-D model.
- Research Organization:
- Oak Ridge National Lab., TN (USA)
- DOE Contract Number:
- W-7405-ENG-26
- OSTI ID:
- 5691992
- Report Number(s):
- ORNL/TM-7112
- Country of Publication:
- United States
- Language:
- English
Similar Records
Method for calculating internal radiation and ventilation with the ADINAT heat-flow code
Limitations to the use of two-dimensional thermal modeling of a nuclear waste repository
THAC-SIP-3D: a three-dimensional, transient heat analysis code using the strongly implicit procedure. [In FORTRAN IV for IBM 360 and 370]
Technical Report
·
Mon Mar 31 23:00:00 EST 1980
·
OSTI ID:59207
Limitations to the use of two-dimensional thermal modeling of a nuclear waste repository
Technical Report
·
Wed Jan 03 23:00:00 EST 1979
·
OSTI ID:6274837
THAC-SIP-3D: a three-dimensional, transient heat analysis code using the strongly implicit procedure. [In FORTRAN IV for IBM 360 and 370]
Technical Report
·
Fri Sep 01 00:00:00 EDT 1978
·
OSTI ID:6619320
Related Subjects
052002* -- Nuclear Fuels-- Waste Disposal & Storage
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES
99 GENERAL AND MISCELLANEOUS
990200 -- Mathematics & Computers
A CODES
COMPUTER CODES
ENERGY TRANSFER
GEOLOGIC DEPOSITS
H CODES
HEAT TRANSFER
MANAGEMENT
NUCLEAR FACILITIES
RADIOACTIVE WASTE DISPOSAL
RADIOACTIVE WASTE FACILITIES
S CODES
T CODES
UNDERGROUND DISPOSAL
WASTE DISPOSAL
WASTE MANAGEMENT
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES
99 GENERAL AND MISCELLANEOUS
990200 -- Mathematics & Computers
A CODES
COMPUTER CODES
ENERGY TRANSFER
GEOLOGIC DEPOSITS
H CODES
HEAT TRANSFER
MANAGEMENT
NUCLEAR FACILITIES
RADIOACTIVE WASTE DISPOSAL
RADIOACTIVE WASTE FACILITIES
S CODES
T CODES
UNDERGROUND DISPOSAL
WASTE DISPOSAL
WASTE MANAGEMENT