Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Field evaluation of a utility spray dryer system. Final report. [Spray dryer/fabric filter system]

Technical Report ·
OSTI ID:5688121
This program, co-funded by the US Environmental Protection Agency and the Electric Power Research Institute, has resulted in an evaluation of a full-scale utility spray dryer/baghouse dry FGD system. The system is installed at the Northern States Power Company's Riverside Station and treats flue gas from a nominal 100 MW of coal-fired power generation. This has been the first independent evaluation of a full-scale spray dryer/baghouse system. For the test program, two different coals were used as boiler fuels. One coal was a subbituminous coal and coke mixture with a nominal 1.2% sulfur content. The second was a 3.4% sulfur Illinois bituminous coal. The test program was conducted from July to October 1983. SO/sub 2/ removal, particulate emissions, sulfuric acid removal and extensive process data were recorded. Low sulfur coal tests indicated that 75% SO/sub 2/ removal was achievable in the short-term at reagent ratios of 0.6 to 0.7, and 90% SO/sub 2/ removal was achievable at a reagent ratio of about 0.8. An average removal of nearly 90% was achieved in short-term tests with high sulfur coal at reagent ratios of 1.3 to 1.4. Calcium chloride addition to the atomizer feed slurry was found to reduce the lime addition requirements for high sulfur tests by approximately 25%. 19 refs., 38 figs., 64 tabs.
Research Organization:
Radian Corp., Austin, TX (USA)
OSTI ID:
5688121
Report Number(s):
EPRI-CS-3954; ON: TI85920647
Country of Publication:
United States
Language:
English

Similar Records

Field evaluation of a utility dry-scrubbing system. Final report, April 1982-November 1984
Technical Report · Wed May 01 00:00:00 EDT 1985 · OSTI ID:6280520

High-sulfur spray dryer Shawnee test program. Volume VI. R-C/TVA spray dryer/ESP evaluation
Technical Report · Tue Dec 31 23:00:00 EST 1985 · OSTI ID:5060608

Spray drying/electrostatic precipitator retrofit on high sulfur coal; Results of 10-MW pilot tests
Conference · Thu Dec 31 23:00:00 EST 1987 · Proceedings of the American Power Conference; (USA) · OSTI ID:6959804