Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Real time bunch length measurements in the SLC linac

Conference ·
OSTI ID:5686673
The longitudinal charge distribution of bunches accelerated in the Stanford Linear Collider (SLC) linac will strongly affect the performance of the Collider. Bunch lengths are chosen in a balance between the deleterious effects of longitudinal and transverse wakefields. The former impacts on the beam energy spread whereas the latter is important to the transverse emittance. Two bunch length measurement ports have been installed in the SLC linac: one in the injector region and one after the emittance damping ring to linac reinjection point. These ports utilize a fused quartz Cerenkov radiator in conjunction with an electrooptic streak camera to permit real time monitoring of single s-band buckets with a resolution of several picoseconds. The design of the radiators and light collection optics is discussed with an emphasis on those issues important to high resolution. Experimental results are presented. 7 refs., 4 figs.
Research Organization:
Stanford Linear Accelerator Center, CA (USA)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
5686673
Report Number(s):
SLAC-PUB-3584; CONF-850504-205; ON: DE85014362
Country of Publication:
United States
Language:
English