Relationship of Fanger's predictive mean vote to various monitored parameters on Blouin case study of thermal performance
Conference
·
OSTI ID:5683114
Brookhaven National Laboratory, as part of its Small Building Field Validation Program for the Department of Energy, gathered hourly data from the Blouin Superinsulated House in South Royalton, Vermont. The thermal performance of this house is evaluated to provide an in-depth analysis of why it works so well from the energy conservation standpoint. It is distinguished by a combination of energy conservation features, including extensive thermal insulation, air infiltration control, and south orientation for solar heating benefit. The experiment results demonstrate that the energy needed for space heating, about 1 Btu per square foot per degree day, is smaller than that of any house yet examined by this program. It is concluded that the building thermal envelope performs nearly as calculated and that the features employed are economically competitive with many low-risk investments. Thermal comfort is evaluated through the use of a model based on the analytical and experimental work of P.O. Fanger, actual monitored data is analyzed and compared to the Predicted Mean Vote. 10 refs., 5 figs.
- Research Organization:
- Brookhaven National Lab., Upton, NY (USA)
- DOE Contract Number:
- AC02-76CH00016
- OSTI ID:
- 5683114
- Report Number(s):
- BNL-36378; CONF-850804-2; ON: DE85012528
- Country of Publication:
- United States
- Language:
- English
Similar Records
Blouin superinsulated house: a case study
Case study of the Blouin superinsulated house
Potential energy savings using comfort-index controls for building heating and cooling systems. Final report
Conference
·
Mon Dec 31 23:00:00 EST 1984
·
OSTI ID:5962457
Case study of the Blouin superinsulated house
Technical Report
·
Thu Sep 01 00:00:00 EDT 1983
·
OSTI ID:6814765
Potential energy savings using comfort-index controls for building heating and cooling systems. Final report
Technical Report
·
Sat Dec 31 23:00:00 EST 1977
·
OSTI ID:6972565
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320101* -- Energy Conservation
Consumption
& Utilization-- Residential Buildings-- (-1987)
BUILDINGS
CONTROL
COVERINGS
DATA
DESIGN
DOUBLE ENVELOPE BUILDINGS
DOUBLE GLAZING
ENERGY CONSUMPTION
EXPERIMENTAL DATA
FEDERAL REGION I
GLAZING
HEAT EXCHANGERS
HEATING
HOUSES
HUMIDITY
INFORMATION
MONITORING
NORTH AMERICA
NUMERICAL DATA
ORIENTATION
RESIDENTIAL BUILDINGS
SHUTTERS
SPACE HEATING
THERMAL INSULATION
USA
VERMONT
320101* -- Energy Conservation
Consumption
& Utilization-- Residential Buildings-- (-1987)
BUILDINGS
CONTROL
COVERINGS
DATA
DESIGN
DOUBLE ENVELOPE BUILDINGS
DOUBLE GLAZING
ENERGY CONSUMPTION
EXPERIMENTAL DATA
FEDERAL REGION I
GLAZING
HEAT EXCHANGERS
HEATING
HOUSES
HUMIDITY
INFORMATION
MONITORING
NORTH AMERICA
NUMERICAL DATA
ORIENTATION
RESIDENTIAL BUILDINGS
SHUTTERS
SPACE HEATING
THERMAL INSULATION
USA
VERMONT