Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Gas cooled fast breeder reactor design for a circulator test facility (modified HTGR circulator test facility)

Technical Report ·
DOI:https://doi.org/10.2172/5671531· OSTI ID:5671531
A GCFR helium circulator test facility sized for full design conditions is proposed for meeting the above requirements. The circulator will be mounted in a large vessel containing high pressure helium which will permit testing at the same power, speed, pressure, temperature and flow conditions intended in the demonstration plant. The electric drive motor for the circulator will obtain its power from an electric supply and distribution system in which electric power will be taken from a local utility. The conceptual design decribed in this report is the result of close interaction between the General Atomic Company (GA), designer of the GCFR, and The Ralph M. Parson Company, architect/engineer for the test facility. A realistic estimate of total project cost is presented, together with a schedule for design, procurement, construction, and inspection.
Research Organization:
General Atomic Co., San Diego, CA (USA)
DOE Contract Number:
AT03-76SF71023
OSTI ID:
5671531
Report Number(s):
GA-A-15647
Country of Publication:
United States
Language:
English