Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Comparison of theory and experiment for photovoltaic/thermal collector performance

Conference ·
OSTI ID:5666552
Detailed performance testing of an air and a liquid type combined photovoltaic/thermal (PV/T) collector has been completed with results of accompanying analytical modeling accurately predicting the experimental data. Thermal efficiencies, with concurrent photovoltaic operation at the maximum power point, are computed in accordance with ASHRAE 93-77 specifications and collector-surface heat-transfer coefficients are determined. Analytical modeling of the two collectors from first principals accounts for the non-ideal bonding of photovoltaic cells to the thermal collector components and for the spacing between cells.
Research Organization:
Massachusetts Inst. of Tech., Lexington (USA). Lincoln Lab.
Sponsoring Organization:
US Energy Research and Development Administration (ERDA)
DOE Contract Number:
EY-76-C-02-4094
OSTI ID:
5666552
Report Number(s):
COO--4094-74; CONF-800106--15
Country of Publication:
United States
Language:
English