Industrial Fuel Gas Demonstration Plant Program. Task III report, demonstration plant mechanical design. Volume VIII. Credit generation

Technical Report ·
OSTI ID:5651425

The function of this section is to convert up to 15 x 10/sup 9/ Btu/day of U-Gas from 300 Btu/scf by additional CO/sub 2/ removal and methanation to 950 Btu/scf. The methanated gas is deposited with MLGW in their natural gas distribution system for Btu credit. This section can also adjust up to 45 x 10/sup 9/ Btu/day of 1031 Btu/scf natural gas, withdrawn from the MLGW natural gas pipeline, by air addition to reduce the heating value to 300 Btu/scf as IFG substitute to assure reliable industrial fuel gas supply to the IFG customers. A portion of the desulfurized U-Gas from gas treating is fed to the credit generation system. The credit generation system consists of the following process units: gas compression, shift conversion, acid gas removal, methanation, rich gas drying and odorization, and the credit withdrawing system.

Research Organization:
Memphis Light, Gas and Water Div., TN (USA)
OSTI ID:
5651425
Report Number(s):
FE-2582-1(Vol.8)
Country of Publication:
United States
Language:
English