skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Characteristics of the amperometric oxygen sensor

Journal Article · · Journal of the Electrochemical Society
DOI:https://doi.org/10.1149/1.1838113· OSTI ID:564113
;  [1]
  1. Lawrence Livermore National Lab., CA (United States). Chemistry and Materials Science Directorate

Solid-state amperometric oxygen sensors have attracted great interest during the last two decades, mostly because of their potential use in lean-burn combustion engines. Some important characteristics of the amperometric oxygen sensor are examined in detail with particular emphasis on the influence of electrode polarization on sensor behavior. First, the authors briefly discuss the theoretical framework describing the operation of the amperometric sensor and then describe operational characteristics and observations of anomalous behavior in light of that framework. For the experimental work, a double-cell configuration with a drilled over was used; the second cell served both as the diffusion barrier and as a potentiometric sensor for monitoring the oxygen partial pressure inside the cavity. It was found that the oxygen partial pressure varied significantly from the cavity entrance to the pumping cell cathode surface. Oxygen depletion inside the cavity strongly influenced the cathode polarization and sensor behavior. Upon application of increasing applied voltage, the maximum pumping capacity of the cathode decreased with oxygen depletion until it became equal to the diffusion-limited current enforced by the diffusion barrier. Upon application of even higher voltages, oxygen could not be further depleted at the cathode surface; no further changes in the system occurred until the onset of electronic conduction in the cell electrolyte, where the current increased once again. Electronic conduction was shown to be the cause of anomalous behavior for the sensor where higher current was observed for lower oxygen concentration. A linear response for the amperometric sensor was realized only for oxygen concentrations in the range 0.1 to 25%.

Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
564113
Journal Information:
Journal of the Electrochemical Society, Vol. 144, Issue 11; Other Information: PBD: Nov 1997
Country of Publication:
United States
Language:
English