Mechanical design and analysis of the 2D cross-section of the SSC collider dipole magnet

Conference ·
DOI:https://doi.org/10.2172/5773608· OSTI ID:5633513
; ; ;  [1]; ;  [2]
  1. Fermi National Accelerator Lab., Batavia, IL (USA)
  2. Superconducting Super Collider Lab., Dallas, TX (USA)
The 50 mm aperture collider dipole magnet uses stainless steel collars to position the conductors at the locations specified by the magnetic design and to prestress the coil to prevent conductor motion under excitation. The collars are supported by the vertically-split yoke and cold mass skin to reduce their deflection under excitation. The collar interior is designed to give the coil its required shape at the operating temperature taking into account all deflections that occur from assembly and cooldown. 13 refs., 2 figs., 1 tab.
Research Organization:
Fermi National Accelerator Lab., Batavia, IL (USA)
Sponsoring Organization:
DOE; USDOE, Washington, DC (USA)
DOE Contract Number:
AC02-76CH03000
OSTI ID:
5633513
Report Number(s):
FNAL/C-91/125; CONF-910505--127; ON: DE91013196
Country of Publication:
United States
Language:
English