Solar pond heat removal using a submerged heat exchanger

Conference ·
OSTI ID:5633207

The results of operating a submerged plastic-tube heat exchanger in the 1080 m/sup 2/ Research Salt Gradient Solar Pond at Argonne National Laboratory are presented. The heat exchange system simulates grain drying, in which the temperature of the ambient air is raised 8 to 15/sup 0/C when it passes through a liquid-to-air heat exchanger that is coupled to the submerged heat exchanger. Approximately 1.0 x 10/sup 11/ J (100 MMBtu) were extracted from the pond, and the operation had no adverse effects on the stability of the salt gradient.