Physical properties of SRC-I slurries under preheater conditions. Final report. [300 to 728/sup 0/K; 150, 1000, and 2500 psig]

Technical Report ·
OSTI ID:5632866
In support of the SRC-I Demonstration Plant Project, rheological and density measurements have been made on recycle solvent made from Kentucky No. 9 coal and on slurries of recycle solvent and Kentucky No. 9 coal at a 1.6 solvent/coal ratio. The measurements were taken at temperatures of 300 to 728/sup 0/K (80 to 850/sup 0/F) and pressures of atmospheric, 1.14 MPa (150 psig), 7.00 MPa (1000 psig), and 17.34 MPa (2500 psig). These calculations are required for preheater and feed pump design of coal demonstration plants and, in particular, by the International Coal Refining Company (ICRC) for the SRC-I demonstration plant design effort. The determinations were made in the Oak Ridge National Laboratory Coal Liquids Flow System (CLFS).