Impact of upgraded in vivo lung measurement capability on an internal dosimetry program
Conference
·
OSTI ID:5632760
Implementation of high-purity germanium (Ge) detectors in place of sodium iodide (NaI) detectors for in vivo lung measurements of low-energy photon-emitting radionuclides resulted in significant improvement in detection capability and corresponding improvements in the monitoring of potentially exposed workers. Lung activities below those detectable with the NaI system were discovered during the first 18 months of operation. In a number of cases, these activities were estimated to represent intakes resulting in lung doses as high as 25% of the 15 rem/y United States Department of Energy Radiation Protection Standard. Evaluation of these lung activities and their associated intakes was substantially more time consuming than originally anticipated due to calibration differences between the Ge and NaI systems and to the difficulty of completing some of the follow-up investigations.
- Research Organization:
- Pacific Northwest Lab., Richland, WA (USA)
- DOE Contract Number:
- AC06-76RL01830
- OSTI ID:
- 5632760
- Report Number(s):
- PNL-SA-12650; CONF-8509212-4; ON: DE86010939
- Country of Publication:
- United States
- Language:
- English
Similar Records
In Vivo Radiobioassay and Research Facility
Upgraded in vivo counting for plutonium, americium and uranium
Coaxial germanium detectors in the Y-12 in vivo monitor
Journal Article
·
Mon Jan 31 23:00:00 EST 2011
· Health Physics. Operational Radiation Safety, 100(2):S35-S40
·
OSTI ID:1006290
Upgraded in vivo counting for plutonium, americium and uranium
Conference
·
Tue Dec 31 23:00:00 EST 1985
·
OSTI ID:6063727
Coaxial germanium detectors in the Y-12 in vivo monitor
Technical Report
·
Mon Aug 13 00:00:00 EDT 1984
·
OSTI ID:6608471
Related Subjects
440102 -- Radiation Instrumentation-- Radiation Dosemeters
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
560161* -- Radionuclide Effects
Kinetics
& Toxicology-- Man
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
BODY
CALIBRATION
DOSES
DOSIMETRY
GE SEMICONDUCTOR DETECTORS
HAPO
HIGH-PURITY GE DETECTORS
LUNGS
MEASURING INSTRUMENTS
NATIONAL ORGANIZATIONS
ORGANS
PERSONNEL DOSIMETRY
RADIATION DETECTORS
RADIATION DOSES
RESPIRATORY SYSTEM
SEMICONDUCTOR DETECTORS
US AEC
US DOE
US ERDA
US ORGANIZATIONS
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
560161* -- Radionuclide Effects
Kinetics
& Toxicology-- Man
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
BODY
CALIBRATION
DOSES
DOSIMETRY
GE SEMICONDUCTOR DETECTORS
HAPO
HIGH-PURITY GE DETECTORS
LUNGS
MEASURING INSTRUMENTS
NATIONAL ORGANIZATIONS
ORGANS
PERSONNEL DOSIMETRY
RADIATION DETECTORS
RADIATION DOSES
RESPIRATORY SYSTEM
SEMICONDUCTOR DETECTORS
US AEC
US DOE
US ERDA
US ORGANIZATIONS