A series of benchmarks against start-up tests have been performed on the Oyster Creek boiling water reactor unit 2 RETRAN model in support of developing an in-house reload capability. The liquid and the pressure regulator models have been benchmarked against level and pressure setpoint changes, where small setpoint perturbations were made at rated power. The purpose of the present benchmark is to check the liquid level behavior during a severe level drop as during void collapse following a scram and to size the bypass valves by benchmarking the valves' contraction coefficient. The main steam isolation valves (MSIVs) closure start-up test was chosen for the former, while the bypass valve test was chosen for the latter. The two benchmarks complete the qualification of the upper downcomer liquid level for small and large level changes and the pressure regulator system for the Oyster Creek RETRAN model.
Research Organization:
GPU Nuclear Corp., Parsippany, NJ
OSTI ID:
5626990
Report Number(s):
CONF-870601-
Conference Information:
Journal Name: Trans. Am. Nucl. Soc.; (United States) Journal Volume: 54
Country of Publication:
United States
Language:
English