Cold trap requirements for PHTS and IHTS sodium purification

Technical Report ·
DOI:https://doi.org/10.2172/5622740· OSTI ID:5622740
Cold trap requirements for the Primary Heat Transfer System (PHTS) and the Intermediate Heat Transfer System (IHTS) are defined. The bases for these requirements are (1) maintaining concentrations of oxygen and hydrogen within given limits, (2) controlling the transport of tritium by coprecipitating it in cold traps together with hydrogen, and (3) providing the necessary volume capacity for collecting impurities. It is concluded that the 60 gpm, FFTF Type I, NaK cooled, cold trap will satisfy the PHTS requirements. For each of the IHTS loops a single, 60 gpm, cold trap is required; and an aircooled trap similar to the FFTF Type I design except for a 3-foot longer crystallizer section has been chosen for this service.
Research Organization:
Atomics International Div., Canoga Park, CA (USA)
DOE Contract Number:
EY-76-C-03-0824-025
OSTI ID:
5622740
Report Number(s):
DOE/TIC-11040; TI-099-811-013
Country of Publication:
United States
Language:
English