Efficiency of a bismuth-germanate scintillator: comparison of Monte Carlo calculations with measurements
Monte Carlo calculations of a bismuth-germanate scintillator's efficiency agree closely with experimental measurements. For this comparison, we studied the absolute gamma-ray photopeak efficiency of a scintillator (7.62 cm long by 7.62 cm in diameter) at several gamma-ray energies from 166 to 2615 keV at distances from 0.5 to 152.4 cm. Computer calculations were done in a two-dimensional cylindrical geometry with the Monte Carlo coupled photon-electron code CYLTRAN. For the experiment we measured 11 sources with simple spectra and precisely known strengths. The average deviation between the calculations and the measurements is 3%. Our calculated results also closely agree with recently published calculated results.
- Research Organization:
- Los Alamos National Lab., NM (USA); Technical Programming Services, Pleasanton, CA (USA)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 5607610
- Report Number(s):
- LA-UR-83-3009; CONF-831015-10; ON: DE84001703
- Country of Publication:
- United States
- Language:
- English
Similar Records
Efficiency of a bismuth-germanate scintillator: comparison of Monte Carlo calculations with measurements
Experimental response functions and response matrices for 2. 54-cm x 2. 54-cm and 7. 62-cm x 7. 62-cm bismuth germanate scintillation detectors. Final report
Bismuth germanate scintillators: applications in nuclear safeguards and health physics
Conference
·
Tue Jan 31 23:00:00 EST 1984
· IEEE Trans. Nucl. Sci.; (United States)
·
OSTI ID:6920063
Experimental response functions and response matrices for 2. 54-cm x 2. 54-cm and 7. 62-cm x 7. 62-cm bismuth germanate scintillation detectors. Final report
Technical Report
·
Mon Oct 01 00:00:00 EDT 1990
·
OSTI ID:5739843
Bismuth germanate scintillators: applications in nuclear safeguards and health physics
Conference
·
Wed May 01 00:00:00 EDT 1985
·
OSTI ID:5844714
Related Subjects
440101* -- Radiation Instrumentation-- General Detectors or Monitors & Radiometric Instruments
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
BISMUTH COMPOUNDS
BISMUTH GERMANATES
DATA ANALYSIS
EFFICIENCY
ENERGY RESOLUTION
GERMANATES
GERMANIUM COMPOUNDS
INORGANIC PHOSPHORS
MEASURING INSTRUMENTS
MONTE CARLO METHOD
OXYGEN COMPOUNDS
PHOSPHORS
RADIATION DETECTORS
RESOLUTION
SCINTILLATION COUNTERS
SCINTILLATIONS
SOLID SCINTILLATION DETECTORS
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
BISMUTH COMPOUNDS
BISMUTH GERMANATES
DATA ANALYSIS
EFFICIENCY
ENERGY RESOLUTION
GERMANATES
GERMANIUM COMPOUNDS
INORGANIC PHOSPHORS
MEASURING INSTRUMENTS
MONTE CARLO METHOD
OXYGEN COMPOUNDS
PHOSPHORS
RADIATION DETECTORS
RESOLUTION
SCINTILLATION COUNTERS
SCINTILLATIONS
SOLID SCINTILLATION DETECTORS